Transmitter barriers
Transmitter barrier
The KONGSBERG DZ Barrier Units are designed to safely provide signal interface and power supply to Kongsberg instrumentation located in hazardous area. The unit connects intrinsically safe 4-20 mA transmitters, and is can also be prepared for HART communication.

DZ-110/U Transmitter Barrier
The Transmitter Barrier is installed in safe area, designed to limit the amount of energy that could appear in an electric circuit that connects to instrumentation located in hazardous area.
The DZ-110/U is a single channel shunt diode safety barrier, intended for energizing a 2-wire, 4-20 mA signal transmitter installed in hazardous area.
Power supply: 24 VDC nom. (18 - 32 VDC)
Input/output current: 0 to 22 mA
ATEX, IECEx and type approved
DZ-120 Zener Barrier
The Zener Barrier is installed in safe area, designed to limit the amount of energy that could appear in an electric circuit that connects to instrumentation located in hazardous area.
The DZ-120 is a single channel shunt diode safety barrier, intended for protecting a 2-wire, 4-20 mA/HART signal transmitter installed in hazardous area.
Power supply: 24 VDC nom. (± 0.5 V)
ATEX, IECEx and type approved