BC360 Functions
BC360 - Power Supply and Battery charger
Functions:
- Under voltage
An alarm is given when the output voltage drops below 20V. The alarm disappears when the voltage rises higher than 21.5V.
- Over voltage
An alarm is activated if output voltage exceeds 32V.
- Over temperature
The unit is protected from over temperature.
- Output circuit breaker
If an output current higher than aprox. 70A occurs, a circuit breaker is released and rectifier is shut off. Alarm is given.
- Input circuit breaker
If an input current higher than 25A occurs, a circuit breaker is released and rectifier is shut off.
- Alarms
Alarm signals are fed to a common potential free output, and are indicated in separate LEDs for:
- Power OK
- Failure
- Current limit
- Input voltage When the input voltage decreases to a given level, the rectifier is shut off. When the voltage returns, the rectifier is turned on again.
- Connectors AC: MS3102E16-10P DC: MS3102E22-2S Mon, Par/NTC and Par: Binder 09-0482-00-08
- Grounding Available in front (M5)
- Acoustic noise Max. 55 dBa @50 Hz
- Frequency range 45 - 420Hz